Divider Tool
Tool Name | Short Name | Inputs Count/Type | Outputs Count/Type/Name |
---|---|---|---|
Divider Tool | DIV |
1 Toolbox event stream |
1 event stream: DIV<i> |

DIV tool functional and wiring diagram
Any I/O Toolbox event stream can be selected as the input source.
The tool feeds one I/O Toolbox event stream named DIV<i>.

DIV tool waveforms
Once enabled, the Divider tool skips the first – I – input events before delivering an event every D input events.
The division factor – D – is defined by DividerToolDivisionFactor
. The default value is 2 and the value range is 1 …
65535.
The initial offset – I – is defined by DividerToolInitialOffset
. The default value is 0 and the value range is 0 …
65535.
The operation state is defined by DividerToolEnableControl
. The default value is Disable
0