Documentation Portal      

What are you looking for?

Isolated Output

Specification of the isolated GPIO output ports

Isolated Output Simplified schematic

The output port implements an isolated contact output.

DC characteristics>

Parameter Conditions Min. Typ. Max. Units
Current       100 mA
Differential voltage Open state -30   30 V
Closed state @ 1 mA     0.4 V
Closed state @ 100 mA     1.0 V
DC isolation voltage   250     V
AC isolation voltage   170     VRMS
NOTE
The output port in the closed state has no current limiter, the user circuit must be designed to avoid excessive currents that could destroy the output port.
The output port remains in the OFF-state until it is under control of the application.

AC characteristics

Parameter Min. Typ. Max. Units
Pulse rate 0   100 kHz
Turn-on time     5 µs
Turn-off time     5 µs

Typical switching performance @ 25°C

Current [mA] Turn ON time [µs] Turn OFF time [µs]
0.5 2.0 4.8
1.0 2.0 3.9
4.0 2.2 3.3
10 2.3 2.7
40 2.3 2.7
100 2.3 2.7

Logical map

The state of the output port is determined as follows:

Logical StateOutput port state
HIGHThe contact switch is closed (ON)
LOWThe contact switch is open (OFF)

Compatible loads

The following loads are compatible with the isolated contact output ports:

Any load within the 30V / 100 mA envelope is accepted. The power originates from an external power source or alternatively from the power delivered through the 12V and GND pins of the I/O connectors.

© 2019 EURESYS s.a.  -  About Documentation  -  Coaxlink 12.1.1.2097