Cycle Timing Diagrams
This topic shows timing diagrams of individual CIC cycles and illustrates the ExposureTime, StrobeDuration and StrobeDelay features for 3 use cases corresponding to positive, zero and negative values of StrobeDelay.

StrobeDelay = 0
The Camera Trigger and the Strobe signals goes high immediately after theStartCycle event .

StrobeDelay > 0
The Camera Trigger signal goes high immediately after the StartCycle event and the Strobe signal goes high after StrobeDelay microseconds.

StrobeDelay < 0
The Strobe signal goes high immediately after the StartCycle event and the Camera Trigger signal goes high after a time delay equal to the opposite value of StrobeDelay microseconds.