Documentation Portal      

What are you looking for?

ExposureTime

Feature Info

Module Category Path Type Access
Device Root / CameraAndIlluminationControl / CycleTiming Float RW

Value Info

Dimension: Time

Unit: µs

Increment: 0.008 µs (8 ns)

Description

Sets/gets the exposure time.

Applies only when CameraControlMethod is RG.

Note: Avoid using exposure time settings outside the exposure time range of the camera.

Note: The upper limit is very high: > 150 hours!

Default value: 1,000.0. (1 millisecond)

See also in the Functional Guide

Cycle Timing Machine

Aligning Camera and Illumination Cycles

See also in the GenICam Reference (Device Module)

CycleTiming Category

StrobeDelay

StrobeDuration

© 2018EURESYS s.a.  -  About Documentation  -  Coaxlink 10.3.1.2052