Documentation Portal      

What are you looking for?

Isolated Output

Specification of the isolated GPIO output ports

Isolated Output Simplified schematic

The output port implements an isolated contact output.

DC characteristics>

Parameter Conditions Min. Typ. Max. Units
Current       100 mA
Differential voltage Open state -30   30 V
Closed state @ 1 mA     0.4 V
Closed state @ 100 mA     1.0 V
DC isolation voltage   250     V
AC isolation voltage   170     VRMS

Note: The output port in the closed state has no current limiter, the user circuit must be designed to avoid excessive currents that could destroy the output port.

Note: The output port remains in the OFF-state until it is under control of the application.

AC characteristics

Parameter Min. Typ. Max. Units
Pulse rate 0   100 kHz
Turn-on time     5 µs
Turn-off time     5 µs

Typical switching performance @ 25°C

Current [mA] Turn ON time [µs] Turn OFF time [µs]
0.5 2.0 4.8
1.0 2.0 3.9
4.0 2.2 3.3
10 2.3 2.7
40 2.3 2.7
100 2.3 2.7

Logical map

The state of the output port is determined as follows:

Logical StateOutput port state
HIGHThe contact switch is closed (ON)
LOWThe contact switch is open (OFF)

Compatible loads

The following loads are compatible with the isolated contact output ports:

Any load within the 30V / 100 mA envelope is accepted. The power originates from an external power source or alternatively from the power delivered through the 12V and GND pins of the I/O connectors.

© 2018EURESYS s.a.  -  About Documentation  -  Coaxlink 10.3.1.2052