Line Driver Physical Output States

The line driver output state depends not only on the logical level of the selected Line Output signal but also on the following I/O block settings: LineFormat, LineMode, and LineInverter.

LineFormat LineMode LineInverter / LineOutput logical level Line driver output state
ISO Output

False / low or True / high

The opto-coupler switch is turned OFF.

False / high or True / low

The opto-coupler switch is turned ON.
TTL
CMOS
Output

False / low or True / high

The I/O line is driven LOW.

False / high or True / low

The I/O line is driven HIGH.
TTL DriveLow

False / low or True / high

The I/O line is driven LOW.

False / high or True / low

The I/O line is not driven.
TTL DriveHigh

False / low or True / high

The I/O line is not driven.

False / high or True / low

The I/O line is driven HIGH.