Documentation Portal      

What are you looking for?

LED Indicators

Applies to:

The bracket is fitted with two green LED’s mounted on a right-angled holder.

On 1623 Grablink DualBase, the LED A is related to acquisition channel A whereas LED B is related to acquisition channel B. On 1624 Grablink Base, 1622 Grablink Full and 1626 Grablink Full XR, the two LED's are related to the same acquisition channel.

LED states descriptions and possible causes

State

Description

Possible causes

OFF

The board is not working.

The board is not powered .

The MultiCam driver is not loaded.

The on-board FPGA is not yet configured.

The board is defective.

No Camera Link clock is received from the camera.

The camera is not connected.

The camera is not powered.

The camera is not initialized yet.

ON

Camera Link clock is received from the camera but both the LVAL and the FVAL signals are missing.

The camera is not initialized yet.

In case of asynchronous reset camera: The frame grabber doesn't correctly deliver the Reset/Expose control signals.

Camera Link clock is received from the camera. There is activity on LVAL or FVAL signals but the board is not acquiring data.

The MultiCam Channel is not in the READY or the ACTIVE state.

The trigger conditions are not satisfied.

BLINKING

The board is acquiring data.

-