MinSpeed
Minimum operating speed of the line-scan system, expressed in Hertz
Parameter Info
Class | Category | Level | Type | Access |
---|---|---|---|---|
Channel | Encoder Control | EXPERT | Integer | Get Only |
Num ID | String Identifier | C, C++ identifier |
---|---|---|
1337 << 14 | MinSpeed | MC_MinSpeed |
Parameter Description
This parameter applies when the motion encoder is in use with rate conversion.
This parameter returns the lower limit of the line-scan system operating range.
The downweb line rate has been chosen as a measurement of the system operating speed.
The MinSpeed parameter declares the minimum downweb line rate the converter is able to support. The OnMinSpeed parameter declares the behavior of the rate converter when it reaches the bottom speed limit.
The maximum speed at which the line-scan camera will be used has to be previously declared with MaxSpeed , that sets the upper limit of the rate converter operating range.