LineTrigLine

Designation of line trigger hardware line from outside system

Parameter Info

Class Category Level Type Access
Channel Encoder Control EXPERT Enumerated Set and Get
Num ID String Identifier C, C++ identifier
1334 << 14 LineTrigLine MC_LineTrigLine

Parameter Description

This parameter designates the terminal sensing the line trigger pulse. The line trigger pulse is processed by the grabber and transferred to the camera as the line reset pulse. Usually, this line trigger signal is generated by a motion encoder.

The LineTrigLine parameter designates where the line trigger pulse usually issued by a motion encoder should be applied.

Parameter Values

NOM

MC_LineTrigLine_NOM

Description

The encoder trigger line is found on the System connector at the nominal terminal pin, according to the LineTrigCtl value.

When LineTrigCtl = TTL, the relevant trigger line is TRG.

When LineTrigCtl = ITTL or I12V, the relevant trigger line is A1.

Description

The encoder trigger line is found on the System connector at the nominal terminal pin, according to the LineTrigCtl value.

When LineTrigCtl = LVDS, the relevant trigger line is the differential input pair TRA2.

When LineTrigCtl = TTL, the relevant trigger line is Enhanced IO2.

When LineTrigCtl = ITTL or I12V, the relevant trigger line is ISOA2.

Description

t designates the DIN1 line when LineTrigCtl =DIFF, the DIN1 and DIN2 pair of differential lines when LineTrigCtl =DIFF_PAIRED, the IIN1 line when LineTrigCtl =ISO, the IIN1 and IIN2 pair of differential lines when LineTrigCtl =ISO_PAIRED.

Default value.

Applicability condition(s)

Condition: LineTrigCtl is set to DIFF, DIFF_PAIRED, ISO, or ISO_PAIRED.

TRG

MC_LineTrigLine_TRG

Description

The encoder trigger line is found on the System connector at the terminal TRG.

Applicability condition(s)

Condition: LineTrigCtl is set to TTL.

CAM

MC_LineTrigLine_CAM

Description

The encoder trigger line is applied to the camera and transported through the SPARE downstream signal.

IO1

MC_LineTrigLine_IO1

Description

The encoder trigger line is found on the System connector at the terminal pin Enhanced IO1.

Applicability condition(s)

Condition: LineTrigCtl is set to TTL.

IO2

MC_LineTrigLine_IO2

Description

The encoder trigger line is found on the System connector at the terminal pin Enhanced IO2.

Applicability condition(s)

Condition: LineTrigCtl is set to TTL.

IO3

MC_LineTrigLine_IO3

Description

The encoder trigger line is found on the System connector at the terminal pin Enhanced IO3.

Applicability condition(s)

Condition: LineTrigCtl is set to TTL.

IO4

MC_LineTrigLine_IO4

Description

The encoder trigger line is found on the System connector at the terminal pin Enhanced IO4.

Applicability condition(s)

Condition: LineTrigCtl is set to TTL.

ISOA1

MC_LineTrigLine_ISOA1

Description

The encoder trigger line is found on the System connector at the terminal pin ISOA1.

Applicability condition(s)

Condition: LineTrigCtl is set to ITTL or I12V.

ISOA2

MC_LineTrigLine_ISOA2

Description

The encoder trigger line is found on the System connector at the terminal pin ISOA2.

Applicability condition(s)

Condition: LineTrigCtl is set to ITTL or I12V.

TRA1

MC_LineTrigLine_TRA1

Description

The encoder trigger line is found on the System connector at the terminal pin pair TRA1.

Applicability condition(s)

Condition: LineTrigCtl is set to LVDS.

TRA2

MC_LineTrigLine_TRA2

Description

The encoder trigger line is found on the System connector at the terminal pin pair TRA2.

Applicability condition(s)

Condition: LineTrigCtl is set to LVDS.

DIN1

MC_LineTrigLine_DIN1

Description

Applicability condition(s)

Condition: LineTrigCtl is set to DIFF.

DIN2

MC_LineTrigLine_DIN2

Description

Applicability condition(s)

Condition: LineTrigCtl is set to DIFF.

DIN1_DIN2

MC_LineTrigLine_DIN1_DIN2

Description

The pair of differential input lines DIN1 and DIN2.

Applicability condition(s)

Condition: LineTrigCtl is set to DIFF_PAIRED.

IIN1

MC_LineTrigLine_IIN1

Description

Applicability condition(s)

Condition: LineTrigCtl is set to ISO.

IIN2

MC_LineTrigLine_IIN2

Description

Applicability condition(s)

Condition: LineTrigCtl is set to ISO.

IIN3

MC_LineTrigLine_IIN3

Description

Applicability condition(s)

Condition: LineTrigCtl is set to ISO.

IIN4

MC_LineTrigLine_IIN4

Description

Applicability condition(s)

Condition: LineTrigCtl is set to ISO.

IIN1_IIN2

MC_LineTrigLine_IIN1_IIN2

Description

The pair of differential input lines IIN1 and IIN2.

Applicability condition(s)

Condition: LineTrigCtl is set to ISO_PAIRED.

IIN3_IIN4

MC_LineTrigLine_IIN3_IIN4

Description

The pair of differential input lines IIN3 and IIN4.

Applicability condition(s)

Condition: LineTrigCtl is set to ISO_PAIRED.