Camera Operation Modes

The classification of the operation modes of the industrial cameras is based on the following MultiCam parameters: Expose and Readout.

Expose

The enumerated parameter Expose specifies the camera exposure principle used by the camera; possible values are:

Value

Description

INTCTL

The line or frame exposure condition is totally controlled by the camera. The exposure duration is set through camera configuration settings.

PLSTRG

The line or frame exposure condition starts upon receiving a pulse from the frame grabber.

WIDTH

The duration of a pulse issued by the frame grabber determines the line or frame exposure condition.

INTPRM

The exposure is permanent.

Readout

The enumerated parameter Readout specifies the camera readout principle used by the camera; possible values are

Value

Description

INTCTL

The frame read-out condition is totally controlled by the camera. The read-out duration is set through camera configuration settings.

Supported Area-Scan Camera Operation Modes

Grablink products support the following combinations of values for area-scan cameras (Imaging = AREA):

CamConfig

Expose

Readout

Description

PxxSC

INTCTL

INTCTL

Synchronous progressive scan, camera-controlled exposure

PxxRC

PLSTRG

INTCTL

Asynchronous progressive scan, camera-controlled exposure

PxxRG

WIDTH

INTCTL

Asynchronous progressive scan, grabber-controlled exposure

Supported Line-Scan Camera Operation Modes

Grablink products support the following combinations of values for (non-TDI) line-scan cameras (Imaging = LINE):

CamConfig

Expose

Readout

Description

LxxxxSP

INTPRM

INTCTL

Free-running or camera-controlled line rate

Permanent exposure or disabled electronic shutter

No control line

LxxxxSC

INTCTL

INTCTL

Free-running or camera-controlled line rate

Camera-controlled exposure with electronic shutter

Single control line

LxxxxRP

INTPRM

PLSTRG

Grabber-controlled camera line rate and exposure

Permanent exposure or disabled electronic shutter

Single control line

LxxxxRC

PLSTRG

INTCTL

Grabber-controlled camera line rate

camera controlled exposure

Single control line

LxxxxRG

WIDTH

INTCTL

Grabber-controlled camera rate and exposure

Camera-controlled exposure with electronic shutter

Single control line

LxxxxRG2

PLSTRG

PLSTRG

Grabber-controlled camera rate and exposure

Camera-controlled exposure with electronic shutter

Two control lines

Supported TDI Line-Scan Camera Operation Modes

Grablink products support the following combinations of values for TDI line-scan cameras (Imaging = TDI):

CamConfig

Expose

Readout

Description

LxxxxSP

INTPRM

INTCTL

Free-running, permanent exposure

LxxxxRP

INTPRM

PLSTRG

Grabber-controlled line-scanning, permanent exposure