Trigger Input
Applies to:
For applications using a hardware acquisition trigger, anyone of the system I/O input ports can be selected as the source for the trigger control circuit of the acquisition channel.
For that usage, use the parameters belonging to the Channel Trigger Control Category .
The trigger source signal can originate from the following type of devices:
● | Through a single high-speed differential input port driven by an RS-422 compatible detector. |
● | Through a single isolated current-sense input port driven by a detector that is not RS-422 compliant. |
The selection of the port is primarily based on the electrical style of the sensor device used as trigger source.
Possible ports assignments
Sourcing device type |
Default port(s) assignment |
Alternate port assignment(s) |
---|---|---|
RS-422 compatible detector |
High-speed diff. input #2 |
High-speed diff. input #1 |
Other detectors |
Isolated input #2 |
Isolated input #1 |
The default port assignment for both electrical styles is different than the one of the line trigger (at least when a single signal is used).