Documentation Portal      

What are you looking for?

Line Rate Modes

The "line rate mode" expresses how the Downweb Line Rate is determined in a line-scan acquisition system.

The user specifies the Line Rate Mode by means of MultiCam parameter LineRateMode. Five Line Rate modes are identified in MultiCam:

LineRateMode

Description

CAMERA

Camera – The downweb line rate is originated by the camera.

PULSE

Trigger Pulse – The downweb line rate originates from a train of pulses applied on the line trigger input belonging to the grabber.

CONVERT

Rate Converter – The downweb line rate originates from a train of pulses applied on the line trigger input and processed by a rate converter belonging to the grabber.

PERIOD

Periodic – The downweb line rate originates from an internal periodic generator belonging to the grabber

EXPOSE

Exposure Time – The downweb line rate is identical to the camera line rate and established by the exposure time settings

© 2019 EURESYS s.a.  -  About Documentation  -  MultiCam 6.16.1.4030