Operating Conditions

Standard operating conditions (0°C ~ 55°C) — 80°C max FPGA temperature

Applies to ClosedPC1629 Coaxlink Duo PCIe/104-EMB, PC1630 Coaxlink Mono, PC1631 Coaxlink Duo, PC1632 Coaxlink Quad, PC1633 Coaxlink Quad G3, PC1635 Coaxlink Quad G3 DF, PC1637 Coaxlink Quad 3D-LLE, PC3623 Coaxlink Quad CXP-12 Value, PC3624 Coaxlink Quad CXP-12 DF, PC3633 Coaxlink Quad CXP-12 3D-LLE and PC3625 Coaxlink QSFP+.

Parameter Conditions Min Max Units
FPGA die temperature     80 [176] °C [°F]
Ambient air temperature   0 [32] 55 [131] °C [°F]
Ambient air humidity Non-condensing 10 90 % RH

Standard operating conditions (0°C ~ 55°C) — 95°C max FPGA temperature

Applies to ClosedPC3602 Coaxlink Octo, PC3603 Coaxlink Quad CXP-12, PC3603-4 Coaxlink Quad CXP-12, PC3620 Coaxlink Quad CXP-12 JPEG, PC3620-4 Coaxlink Quad CXP-12 JPEG, PC3621 Coaxlink Mono CXP-12 and PC3622 Coaxlink Duo CXP-12.

Parameter Conditions Min Max Units
FPGA die temperature     95 [203] °C [°F]
Ambient air temperature   0 [32] 55 [131] °C [°F]
Ambient air humidity Non-condensing 10 90 % RH

Standard operating conditions (0°C ~ 55°C) — 80°C max FPGA temperature — 250 lfm min. airflow

Applies to ClosedPC1633-LH Coaxlink Quad G3 LH.

Parameter Conditions Min Max Units
FPGA die temperature     80 [176] °C [°F]
Ambient air temperature 150 LFM minimum
required airflow
0 [32] 55 [131] °C [°F]
Ambient air humidity Non-condensing 10 90 % RH

Standard operating conditions (0°C ~ 55°C) — 95°C max FPGA temperature — 150 lfm min. airflow

Applies to ClosedPC3621-LH Coaxlink Mono CXP-12 LH.

Parameter Conditions Min Max Units
FPGA die temperature     95 [203] °C [°F]
Ambient air temperature 150 LFM minimum
required airflow
0 [32] 55 [131] °C [°F]
Ambient air humidity Non-condensing 10 90 % RH

Standard operating conditions (0°C ~ 55°C) — 95°C max FPGA temperature — 250 lfm min. airflow

Applies to ClosedPC3622-LH Coaxlink Duo CXP-12 LH.

Parameter Conditions Min Max Units
FPGA die temperature     95 [203] °C [°F]
Ambient air temperature 250 LFM minimum
required airflow
0 [32] 55 [131] °C [°F]
Ambient air humidity Non-condensing 10 90 % RH

Standard operating conditions (0°C ~ 55°C)

Applies to ClosedPC1625 DB25F I/O Adapter Cable, PC1636 InterPC C2C-Link Adapter, PC3300 HD26F I/O module for Coaxlink Duo PCIe/104, PC3301 Thermal drain (Model 1) for Coaxlink Duo PCIe/104, PC3302 DIN1.0/2.3 Coaxial cable for Coaxlink Duo PCIe/104, PC3303 C2C-Link Ribbon Cable, PC3304 HD26F I/O Adapter Cable, PC3610 HD26F I/O Extension Module - TTL-RS422, PC3612 HD26F I/O Extension Module - TTL-CMOS5V-RS422, PC3613 JTAG Adapter Xilinx for Coaxlink, PC3614 HD26F I/O Extension Module - Standard I/O Set and PC3618 HD26F I/O Extension Module - Fast I/O.

Parameter Conditions Min Max Units
Ambient air temperature   0 [32] 55 [131] °C [°F]
Ambient air humidity Non-condensing 10 90 % RH
The thermal design of the host PC must ensure that, at any time, the FPGA die temperature never exceeds the recommended limit.
Exceeding the upper limit of the FPGA die temperature can permanently damage the card.