Multiple Cycle Timings
(1-camera)
(1-camera), (1-camera, custom-logic), (2-camera), (3-camera), (4-camera), (5-camera), (5-camera, 5D22211), (6-camera), (8-camera)
(1-camera), (1-camera, custom-logic), (1-camera, line-scan), (2-camera), (2-camera, custom-logic), (4-camera), (4-camera, custom-logic)
(4-camera)
(1-camera), (1-camera, line-scan), (2-camera), (4-camera)
(1-camera), (1-df-camera)
(1-camera), (1-camera, custom-logic)
In the Cycle Timing Category of the Device Module, the CycleTimingSelector parameter acts as a selector for ExposureTime, StrobeDelay and StrobeDuration.
The CIC of above listed firmware variants allows to define up to 16 different timing sets!
By default, CycleTimingSelector = 1.
To activate the multiple cycle timings feature, set the CycleTimingCount parameter to any value between 2 and 16 according to the number of cycle timings to be executed.
The CIC uses successively and repeatedly the different timing definitions starting with index 0 up to the value of CycleTimingCount -1.
See also: Multiple Timings Example for more explanations and timing diagrams.