Single Cycle
Timing diagrams of single CIC cycles
This topic shows timing diagrams of individual CIC cycles and illustrates the ExposureTime, StrobeDuration and StrobeDelay features for 3 use cases corresponding to positive, zero and negative values of StrobeDelay.
In-phase Strobe
In-phase Strobe signal
The Camera Trigger and the Strobe signals goes high immediately after the StartCycle event .
Late Strobe
Late Strobe signal
The Camera Trigger signal goes high immediately after the StartCycle event and the Strobe signal goes high after StrobeDelay microseconds.
Early Strobe
Early Strobe signal
The Strobe signal goes high immediately after the StartCycle event and the Camera Trigger signal goes high after a time delay equal to the opposite value of StrobeDelay microseconds.