Multi-tap CoaXPress Cameras
(1-camera)
(1-camera)
(1-camera), (1-df-camera)
(1-camera)
Multi-tap is controlled through the following GenApi features of the MultiTapControl category of the Coaxlink Data Stream module:
● | DeviceTapGeometry: Image scan format. Supported values: |
□ | 1X_1Y: Single tap. Default value. |
□ | 1X_2YE: Two zones across vertical direction, pixel extractors at both top and bottom lines. |
● | Image1StreamID: Stream ID of first tap (ignored when DeviceTapGeometry is Geometry_1X_1Y). |
● | Image2StreamID: Stream ID of second tap (ignored when DeviceTapGeometry is Geometry_1X_1Y). |
See also: Transmission Methods of 1X_2YE Images (Coaxlink series)