I/O Power Output
Description
A non-isolated +12 V power output is available on every I/O connector.
The power originates from an external 12 V power supply plugged into the Auxiliary Power Input connector. It is distributed from a common electronic fuse to all the I/O connectors.
The electronic fuse provides the following protections:
● | Limits the inrush current during power on sequence |
● | Protects the frame grabber and the power source against overload |
● | Protects the frame grabber and the power source against short-circuits. |
The sum of the load currents drawn from all the 12 V outputs of the I/O connectors must be lower or equal to the specified maximum output current.
Specification
Parameter | Conditions | Min. | Typ. | Max. | Units |
---|---|---|---|---|---|
Aggregated output current | Operating temperature range | 1.0 | A | ||
Voltage drop across the electronic fuse | Max. output current | 0.2 | V |
NOTE: | The above specification applies over the whole operating temperature range of the frame grabber. |
A non-isolated +12 V power output is available on every I/O connector.
The power originates from an external 12 V power supply plugged into the Auxiliary Power Input connector. It is distributed from a common resettable fuse to all the I/O connectors.
The resettable fuse provides the following protections:
● | Limits the inrush current during power on sequence |
● | Protects the frame grabber and the power source against overload |
● | Protects the frame grabber and the power source against short-circuits. |
● | The resettable fuse is a positive temperature coefficient device 1.85 A PTC. |
The sum of the load currents drawn from all the 12 V outputs of the I/O connectors must be lower or equal to the specified maximum output current.
Specification
Parameter | Conditions | Min. | Typ. | Max. | Units |
---|---|---|---|---|---|
Aggregated output current | Operating temperature range | 1.0 | A | ||
Voltage drop across the electronic fuse | Max. output current | 0.2 | V |
NOTE: | The above specification applies over the whole operating temperature range of the frame grabber. |