I/O Power Output

I/O Power Output (Version 1)

Applies to Closed1628 Grablink Duo, 1630 Coaxlink Mono, 1631 Coaxlink Duo, 1632 Coaxlink Quad, 1633 Coaxlink Quad G3, 1633-LH Coaxlink Quad G3 LH, 1635 Coaxlink Quad G3 DF, 1637 Coaxlink Quad 3D-LLE, 3602 Coaxlink Octo, 3603 Coaxlink Quad CXP-12, 3603-4 Coaxlink Quad CXP-12, 3620 Coaxlink Quad CXP-12 JPEG, 3620-4 Coaxlink Quad CXP-12 JPEG, 3621 Coaxlink Mono CXP-12, 3621-LH Coaxlink Mono CXP-12 LH, 3622 Coaxlink Duo CXP-12, 3622-LH Coaxlink Duo CXP-12 LH and 3625 Coaxlink QSFP+.

Description

A non-isolated +12 V power output is available on every I/O connector.

The power originates from an external 12 V power supply plugged into the Auxiliary Power Input connector. It is distributed from a common electronic fuse to all the I/O connectors.

The electronic fuse provides the following protections:

Limits the inrush current during power on sequence
Protects the frame grabber and the power source against overload
Protects the frame grabber and the power source against short-circuits.

The sum of the load currents drawn from all the 12 V outputs of the I/O connectors must be lower or equal to the specified maximum output current.

Specification

Parameter Conditions Min. Typ. Max. Units
Aggregated output current Operating temperature range     1.0 A
Voltage drop across the electronic fuse Max. output current     0.2 V
NOTE: The above specification applies over the whole operating temperature range of the frame grabber.

I/O Power Output (Version 2)

Applies to Closed3623 Coaxlink Quad CXP-12 Value and 3624 Coaxlink Quad CXP-12 DF.

A non-isolated +12 V power output is available on every I/O connector.

The power originates from an external 12 V power supply plugged into the Auxiliary Power Input connector. It is distributed from a common resettable fuse to all the I/O connectors.

The resettable fuse provides the following protections:

Limits the inrush current during power on sequence
Protects the frame grabber and the power source against overload
Protects the frame grabber and the power source against short-circuits.
The resettable fuse is a positive temperature coefficient device 1.85 A PTC.

The sum of the load currents drawn from all the 12 V outputs of the I/O connectors must be lower or equal to the specified maximum output current.

Specification

Parameter Conditions Min. Typ. Max. Units
Aggregated output current Operating temperature range     1.0 A
Voltage drop across the electronic fuse Max. output current     0.2 V
NOTE: The above specification applies over the whole operating temperature range of the frame grabber.