Isolated Output

Applies to Closed1628 Grablink Duo, 1630 Coaxlink Mono, 1631 Coaxlink Duo, 1632 Coaxlink Quad, 1633 Coaxlink Quad G3, 1633-LH Coaxlink Quad G3 LH, 1635 Coaxlink Quad G3 DF, 1637 Coaxlink Quad 3D-LLE, 3602 Coaxlink Octo, 3603 Coaxlink Quad CXP-12, 3603-4 Coaxlink Quad CXP-12, 3620 Coaxlink Quad CXP-12 JPEG, 3620-4 Coaxlink Quad CXP-12 JPEG, 3621 Coaxlink Mono CXP-12, 3621-LH Coaxlink Mono CXP-12 LH, 3622 Coaxlink Duo CXP-12, 3622-LH Coaxlink Duo CXP-12 LH, 3623 Coaxlink Quad CXP-12 Value, 3624 Coaxlink Quad CXP-12 DF, 3625 Coaxlink QSFP+, 3300 HD26F I/O module for Coaxlink Duo PCIe/104, 3614 HD26F I/O Extension Module - Standard I/O Set and 3618 HD26F I/O Extension Module - Fast I/O.

Isolated Output Simplified schematic

The output port implements an isolated contact output.

DC characteristics

Parameter Conditions Min. Typ. Max. Units
Current       100 mA
Differential voltage Open state -30   30 V
Closed state @ 1 mA     0.4 V
Closed state @ 100 mA     1.0 V
The output port in the closed state has no current limiter, the user circuit must be designed to avoid excessive currents that could destroy the output port.
The output port remains in the OFF-state until it is under control of the application.

AC characteristics

Parameter Min. Typ. Max. Units
Pulse rate 0   100 kHz
Turn-on time     5 µs
Turn-off time     5 µs

Typical switching performance @ 25°C

Current [mA] Turn ON time [µs] Turn OFF time [µs]
0.5 2.0 4.8
1.0 2.0 3.9
4.0 2.2 3.3
10 2.3 2.7
40 2.3 2.7
100 2.3 2.7

Isolation characteristics

Parameter Value
Isolation grade Functional
Max. DC voltage 250 V
Max. AC voltage 170 VRMS

The functional isolation is only for the circuit technical protection. It does not provide an isolation that can protect a human being from electrical shock!

Logical map

The state of the output port is determined as follows:

Logical StateOutput port state
HIGHThe contact switch is closed (ON)
LOWThe contact switch is open (OFF)

Compatible loads

The following loads are compatible with the isolated contact output ports:

Any load within the 30 V / 100 mA envelope is accepted. The power originates from an external power source or alternatively from the power delivered through the 12 V and GND pins of the I/O connectors.