Camera Link LED lamps
Each connector of the Camera Link Host Interface is associated with a LED lamp mounted on the bracket.
LED lamps mode control
The LampMode feature of the Interface module defines the lamps operation mode:
● | When set to Standard (default value), the lamps indicate the state of the Camera Link connection. |
● | When set to Dark, all lamps are turned off. |
● | When set to Error, all lamps are turned off unless error conditions are detected. |
● | When set to Custom, all lamps are controlled by LampCustomValue, a bitfield where each bit is mapped onto a lamp with 1 for orange and 0 for off by the LampCustomLedA … LampCustomLedH boolean features. |
Camera Link Host Indicator LED lamps states
States description
Symbol | Indication, color(s) | State |
---|---|---|
Off | No power | |
Solid, orange | System booting | |
AlternateFlash_12_5, green / orange1 |
Connection detection in progress; PoCL active |
|
Flash_12_5, orange2 |
Connection detection in progress; PoCL not in use | |
Solid, green | Device / Host connected (Serdes locked), but no data being transferred | |
Flash_1, orange | Device / Host connected (Serdes locked), waiting for event (e.g. trigger, exposure pulse) | |
Flash_12_5, green | Device / Host (Serdes locked), data being transferred | |
Flash_0_5, red | Invalid connector B configuration | |
Flash_12_5, red | System error (e.g. internal error) |
Flashing states timing definitions
Indication | Frequency | Duty Cycle |
---|---|---|
Flash_12_5 |
12.5 Hz |
25% (20 milliseconds on, 60 milliseconds off) |
Flash_1 | 1 Hz | 20% (200 milliseconds on, 800 milliseconds off) |
Flash_0_5 | 0.5 Hz | 50% (1 second on, 1 second off) |
AlternateFlash_12_5 |
12.5 Hz |
25% (20 milliseconds on color 1, 60 milliseconds off, 20 milliseconds on color 2, 60 milliseconds off) |