Power Output Specifications
The following table provides the available output power for each product:
□ | The I/O column specifies the maximum available output power dedicated to external I/O powering |
□ | The Camera column specifies the maximum available output power dedicated to camera powering. |
Product | I/O | Camera | Units |
---|---|---|---|
|
12 | 17 | W |
|
12 | 2 x 17 | W |
|
12 | 4 x 17 | W |
|
12 | 4 x 17 | W |
|
12 | 4 x 17 | W |
|
N/A | 2 x 17 | W |
|
12 | 4 x 17 | W |
|
12 | 4 x 17 | W |
|
12 | 8 x 17 | W |
|
12 | 4 x 17 | W |
|
12 | 4 x 17 | W |
|
12 | 4 x 17 | W |
|
12 | 4 x 17 | W |
|
12 | 1 x 25 | W |
|
12 | 2 x 17 | W |
|
12 | N/A | W |
|
12 | N/A | W |
|
12 | N/A | W |
I/O +12 V power output specification
Parameter | Conditions | Min. | Typ. | Max. | Units |
---|---|---|---|---|---|
Aggregated output current | Operating temperature range | 1.0 | A | ||
Voltage drop across the electronic fuse | Max. output current | 0.2 | V |
The above specification applies over the whole operating temperature range of the Coaxlink card.