Auxiliary Power Input
Auxiliary power input requirements
The following table provides the 'worst case' auxiliary power consumption for each product:
□ | The I/O power column specifies the maximum required input power dedicated to external I/O powering. |
□ | The Camera power column specifies the maximum required input power dedicated to camera powering. This number takes care of the power conversion efficiency. |
Product | Connector | Nominal voltage [V] |
I/O power [W] |
Camera power [W] |
Total power [W] |
---|---|---|---|---|---|
1630 Coaxlink Mono | PEG | 12 | 12 | 19 | 31 |
1631 Coaxlink Duo | PEG | 12 | 12 | 2 x 19 | 50 |
1632 Coaxlink Quad | PEG | 12 | 12 | 4 x 19 | 88 |
1633 Coaxlink Quad G3 | PEG | 12 | 12 | 4 x 19 | 88 |
1633-LH Coaxlink Quad G3 LH | PEG | 12 | 12 | 4 x 19 | 88 |
1629 Coaxlink Duo PCIe/104-EMB | MOLEX | 24 | N/A | 2 x 17 | 34 |
1635 Coaxlink Quad G3 DF | PEG | 12 | 12 | 4 x 19 | 88 |
1637 Coaxlink Quad 3D-LLE | PEG | 12 | 12 | 4 x 19 | 88 |
3602 Coaxlink Octo | PEG* | 12 | 12 | 8 x 19 | 164 |
3603 Coaxlink Quad CXP-12 | PEG* | 12 | 12 | 4 x 19 | 88 |
3603-4 Coaxlink Quad CXP-12 | PEG* | 12 | 12 | 4 x 19 | 88 |
3620 Coaxlink Quad CXP-12 JPEG | PEG* | 12 | 12 | 4 x 19 | 88 |
3620-4 Coaxlink Quad CXP-12 JPEG | PEG* | 12 | 12 | 4 x 19 | 88 |
3621 Coaxlink Mono CXP-12 | PEG* | 12 | 12 | 1 x 25 | 37 |
3621-LH Coaxlink Mono CXP-12 LH | PEG* | 12 | 12 | 1 x 25 | 37 |
3622 Coaxlink Duo CXP-12 | PEG* | 12 | 12 | 2 x 19 | 50 |
3622-LH Coaxlink Duo CXP-12 LH | PEG* | 12 | 12 | 2 x 19 | 50 |
3625 Coaxlink QSFP+ | PEG | 12 | 12 | N/A | 12 |
PEG*: PEG connectors without SenseIN input!
Requirements for PEG connector
The network is fed by a 12 V external power supply attached to the auxiliary power input connector using a power cable terminated by a 6-pin PEG plug connector. A protection fuse inserted at the input side prevents potential fire hazards.
Parameter | Min. | Typ. | Max. | Units |
---|---|---|---|---|
Voltage | 11.0 | 12.0 | 13.0 | V |
On the card side of the power cable, check carefully the voltage on each pin of the 6-pin PEG connector plug before insertion!
See also: Avoid Mixing Power Supply Cables
Requirements (MOLEX connector)
The network is fed by a 24 V external power supply attached to the auxiliary power input connector using a power cable terminated by a 4-pin MOLEX plug connector. A protection fuse inserted at the input side prevents potential fire hazards.
Parameter | Min. | Typ. | Max. | Units |
---|---|---|---|---|
Voltage | 23 | 24 | 25 | V |
On the card side of the power cable, check carefully the voltage on each pin of the 4-pin Molex connector plug before insertion!
See also: Avoid Mixing Power Supply Cables
Monitoring the auxiliary power input
The AuxiliaryPower12VInput GenApi feature of the Interface module reports the status of the "12V Auxiliary Power Input" measured after the input fuse.
The AuxiliaryPowerInput GenApi feature of the Interface module reports the status of the auxiliary power input cable connection. This feature is only available for products having a PEG connector with a SenseIN input.
The SenseIN input of the PEG connector is used for power source cable presence detection. It should be grounded at the power supply level.
Related topics - Hardware Manual
PEG6F PoCXP/GPIO Auxiliary Power Input Connector
PEG6F PoCXP/GPIO Auxiliary Power Input Connector w/o SenseIN
Related topics - Functional guide
Related topics - GenApi Reference (Interface module)