PreStrobe_us
Time delay, expressed in microseconds, before the pulse defined by StrobePos
Parameter Info
Class | Category | Level | Type | Access |
---|---|---|---|---|
Channel | Strobe Control | EXPERT | Integer | Set and Get |
Num ID | String Identifier | C, C++ identifier |
---|---|---|
2190 << 14 | PreStrobe_us | MC_PreStrobe_us |
Parameter Description
This parameter declares the delay of the beginning of the strobe pulse before the normal beginning defined by StrobePos . If long enough, it creates a "pre-exposure" phase before actual "start of exposure phase" (SAP).
● | For area-scan cameras, this parameter relates to the illumination during the frame exposure period. |
● | For line-scan cameras, this parameter is irrelevant. |
Parameter Values
Value | Description |
---|---|
0 |
Minimum range value. |
10000 |
10,000 microseconds (=10 milliseconds) Maximum range value. |