PreStrobe_us

Time delay, expressed in microseconds, before the pulse defined by StrobePos

Parameter Info

Class Category Level Type Access
Channel Strobe Control EXPERT Integer Set and Get
Num ID String Identifier C, C++ identifier
2190 << 14 PreStrobe_us MC_PreStrobe_us

Parameter Description

This parameter declares the delay of the beginning of the strobe pulse before the normal beginning defined by StrobePos . If long enough, it creates a "pre-exposure" phase before actual "start of exposure phase" (SAP).

For area-scan cameras, this parameter relates to the illumination during the frame exposure period.
For line-scan cameras, this parameter is irrelevant.

Parameter Values

Value Description
0

Minimum range value.

10000

10,000 microseconds (=10 milliseconds)

Maximum range value.