[PC1629] Coaxlink Duo PCIe/104-EMB Properties

Common product properties

Property description Property value
General properties
Brand name Euresys
Product code and name [PC1629] Coaxlink Duo PCIe/104-EMB
Product layout [PC1629] Coaxlink Duo PCIe/104-EMB
Firmware name - Product field Coaxlink Duo PCIe/104 -EMB
Serial nr. prefix KDI
Documentation package eGrabber
Documentation section Coaxlink series mini-site
Product driver eGrabber
Product series Coaxlink
Product sub-series CXP-6
Product class Frame Grabber
Product status End of life - No longer sold
Product leaflet D221 eGrabber PCIe/104 Installation Guide
First release Coaxlink 6.0
Product notes End-of-life product
PLC Launch 2017-02-01
PLC End-Of-Life 2026-11-30
Frame Grabber properties
Card profile of the PCIe/104 product std
PCI interface type 4-lanes PCI Express Gen2
On-board memory capacity [Megabyte] 512
Camera Interface properties
Standard CoaXPress
Physical layer CoaXPress CXP-6
Camera interface connector(s) type MCX-2
Camera powering standard PoCXP
Electrical properties
Power distribution scheme [PC1629] Coaxlink Duo PCIe/104-EMB
PCI Express +12 V typical input power [Watt] 8.4
GPIO properties
Compatible I/O Modules 3300
Mechanical properties
Cooling method Conduction
Dimensions axes PCB: Lenght x Height
Dimensions [mm] 96 x 90
Dimensions [in] 3,775 x 3,555
Gross weight [kg] 0.162
Net weight [kg] 0.062
Connectors properties
Camera connector instance CoaXPress MCX 2 Connector
C2C-Link connector instance C2C-Link Connector
Power connector Camera Power Input Connector
Environmental properties
Storage conditions Standard
Operating conditions Standard 0°C-55°C | 80°C max FPGA temperature
Estimated heat power (No camera power delivery) [W] 8.4
Estimated heat power (With max. camera power delivery) [W] 8.4
EMC compliance for Europe EN55032 Class A emission | EN50121-3-2, EN61000-6-2 immunity (CE_A2 group)
EMC compliance for US Class A emission (FCC_A group)
REACH compliance EU REACH Regulation (EC) No 1907/2006 with Lead exemption
RoHS compliance EU/2015/863 (RoHS) of the 2011/65/EU directive with 6(a)-1, 7(a) and 7(c)-1 exemptions
Indicators properties
12V power LED Y
Accessories properties
PC3300 HD26F I/O module for Coaxlink Duo PCIe/104 Compatible
PC3301 Thermal drain (Model 1) for Coaxlink Duo PCIe/104 Compatible
PC3302 DIN1.0/2.3 Coaxial cable for Coaxlink Duo PCIe/104 Compatible
PC3303 C2C-Link Ribbon Cable Compatible

Coaxlink Duo PCIe/104-EMB (1-camera) firmware properties

Property description Property value
General properties
Firmware name (Short version) Coaxlink Duo PCIe/104-EMB (1-camera)
Firmware name (Full version) PC1629 - Coaxlink Duo PCIe/104-EMB (1-camera)
Variant name 1-camera
Camera type Area-scan
First release 6.0
Current firmware revision number 530
Camera Interface properties
HCMAP (Host Connection MAP) 1D2
HCMAP description One 1- or 2-connection
HCMAP - Device count field 1
HCMAP - Connection(s) per device field 2C
HCMAP - Stream count field 1S
Pixel Processing properties
Lookup-table pixel processing Available
I/O Toolbox properties
I/O toolbox Line Input tools count 8
I/O toolbox Quadrature Decoder tools count 1
I/O toolbox User Actions Scheduler tools count 1
I/O toolbox Delay tools count 2
I/O toolbox Divider tools count 1
I/O toolbox Multiplier/Divider tools count 1
I/O toolbox C2C-Link Synchronization tools count 2
Acquisition properties
Image acquisition type Area-scan
Buffer filling rule Discard remaining data
On-board memory partition scheme One device, one 'Image data' partition
Maximum number of CIC cycle timings 1
Default width-increment step [Byte] 8

Coaxlink Duo PCIe/104-EMB (1-camera, line-scan) firmware properties

Property description Property value
General properties
Firmware name (Short version) Coaxlink Duo PCIe/104-EMB (1-camera, line-scan)
Firmware name (Full version) PC1629 - Coaxlink Duo PCIe/104-EMB (1-camera, line-scan)
Variant name 1-camera, line-scan
Camera type Line-scan
First release 6.0
Current firmware revision number 530
Camera Interface properties
HCMAP (Host Connection MAP) 1D2
HCMAP description One 1- or 2-connection
HCMAP - Device count field 1
HCMAP - Connection(s) per device field 2C
HCMAP - Stream count field 1S
Pixel Processing properties
Lookup-table pixel processing Available
I/O Toolbox properties
I/O toolbox Line Input tools count 8
I/O toolbox Quadrature Decoder tools count 1
I/O toolbox User Actions Scheduler tools count 1
I/O toolbox Delay tools count 2
I/O toolbox Divider tools count 1
I/O toolbox Multiplier/Divider tools count 1
I/O toolbox C2C-Link Synchronization tools count 3
Acquisition properties
Image acquisition type Line-scan
Buffer filling rule Continue into a new buffer
On-board memory partition scheme One device, one 'Image data' partition
Maximum number of CIC cycle timings 1
Default width-increment step [Byte] 8

Coaxlink Duo PCIe/104-EMB (2-camera) firmware properties

Property description Property value
General properties
Firmware name (Short version) Coaxlink Duo PCIe/104-EMB (2-camera)
Firmware name (Full version) PC1629 - Coaxlink Duo PCIe/104-EMB (2-camera)
Variant name 2-camera
Camera type Area-scan
First release 6.0
Current firmware revision number 530
Camera Interface properties
HCMAP (Host Connection MAP) 2D11
HCMAP description One or two 1-connection
HCMAP - Device count field 2
HCMAP - Connection(s) per device field 1C
HCMAP - Stream count field 1S
Pixel Processing properties
Lookup-table pixel processing Available
I/O Toolbox properties
I/O toolbox Line Input tools count 8
I/O toolbox Quadrature Decoder tools count 2
I/O toolbox User Actions Scheduler tools count 1
I/O toolbox Delay tools count 2
I/O toolbox Divider tools count 2
I/O toolbox Multiplier/Divider tools count 2
I/O toolbox C2C-Link Synchronization tools count 2
Acquisition properties
Image acquisition type Area-scan
Buffer filling rule Discard remaining data
On-board memory partition scheme Two devices, one 'image data' partition per device
Maximum number of CIC cycle timings 1
Default width-increment step [Byte] 8