ERectangleGauge::GetKnownAngle

ERectangleGauge::SetKnownAngle

Flag indicating whether the rotation angle of the rectangle to be fitted is known or not.

Namespace: Euresys::Open_eVision_2_10

[C++]

BOOL GetKnownAngle()

void SetKnownAngle(BOOL bKnownAngle)

Remarks

A rectangle model to be fitted may have a well-known orientation. It is possible to impose the value of this rotation angle, thus removing one degree of freedom. The rectangle fitting gauge orientation is set by means of the ERectangleGauge.Angle property.
The sign of the rotation angle depends whether the field of view is calibrated or not.
* When the field of view is calibrated, the coordinate system is said to be direct, the abscissa extends rightwards and the ordinate extends upwards. In this case, an anticlockwise rotation leads to a positive angle value.
* When the field of view is not calibrated, the coordinate system is said to be inverse, the abscissa extends rightwards and the ordinate extends downwards. In this case, a clockwise rotation leads to a positive angle value.

ERectangleGauge.KnownAngle

Flag indicating whether the rotation angle of the rectangle to be fitted is known or not.

Namespace: Euresys.Open_eVision_2_10

[C#]

bool KnownAngle

{ get; set; }

Remarks

A rectangle model to be fitted may have a well-known orientation. It is possible to impose the value of this rotation angle, thus removing one degree of freedom. The rectangle fitting gauge orientation is set by means of the ERectangleGauge.Angle property.
The sign of the rotation angle depends whether the field of view is calibrated or not.
* When the field of view is calibrated, the coordinate system is said to be direct, the abscissa extends rightwards and the ordinate extends upwards. In this case, an anticlockwise rotation leads to a positive angle value.
* When the field of view is not calibrated, the coordinate system is said to be inverse, the abscissa extends rightwards and the ordinate extends downwards. In this case, a clockwise rotation leads to a positive angle value.

Which API shall we display?